Ονομασία μάρκας: | Sinuo |
Αριθμός μοντέλου: | ΣΕ2117 |
Τροποποιημένο: | 1 |
Όροι πληρωμής: | Τ/Τ |
Ικανότητα εφοδιασμού: | 10 σετ ανά μήνα |
Electric Vehicle Load Cabinet for Breaking Capacity Test IEC 62196
Complied Standards & Clauses
IEC 62196-1 Ed.4CDV 2020 clause 22.
Product Overview
Load Cabinet for Breaking Capacity Test – IEC 62196-1:2020 Compliant
This load cabinet is designed in strict accordance with IEC 62196-1:2020 Clause 22, making it ideal for breaking capacity tests on electrical components such as plugs, sockets, switches, connectors, and relays. It features single-phase power output and single-phase load input, and supports resistive, inductive, or capacitive load configurations to simulate a wide range of operating conditions.
Constructed from durable iron plates with a powder-coated finish, the cabinet ensures long-term reliability. It is equipped with four lockable caster wheels for easy mobility and stable positioning. The upper control panel includes an intuitive layout with a power switch, load switch, digital voltmeter, ammeter, power meter, power factor meter, power-on counter, and load type selectors. Operators can easily choose between load modes and fine-tune capacitance via dedicated switches.
Internally, the cabinet integrates a comprehensive resistor–inductor–capacitor (RLC) load system, supported by a high-efficiency forced-air cooling mechanism. All components, including control circuit boards and output wiring terminals, are neatly arranged for safe and efficient operation.
This versatile and robust testing solution is suitable for laboratories, R&D centers, and quality control environments requiring precise and reliable load simulation. Customization is available upon request.
Technical Parameters
Power Supply |
Three-phase four-wire AC380 ± 10% / 50Hz. Note: must have neutral wire. |
Test Station | 3 stations, independent output |
Electrical Control Method | Button control |
Output Voltage | 0~300V, accuracy ±0.5%, digital display |
Output Current | 0~30A, accuracy ±0.5%, digital display |
Power Factor | 0.3~0.98, accuracy ±0.5%, digital display |
Output Power | 0~10KW, accuracy ±0.5%, digital display |
Load Type | Resistive, inductive, capacitive three-in-one, switchable |
Capacitive Load | 70uf, 140uf,7.3uf are switchable |
Load Output | Optional for each load output and separate load output |
Test Times | 0~999999 times, can be preset |
Load Power Supply Capacity | 3*10KVA |
Overrun Alarm | Upper limit of output current is 30A, automatically cut off if over 32A |
Dimensions & Weight | Approximately:1000×800×1800 (mm) W×D×H, 350kg |